ADD HYSTERESIS TO YOUR MANOMETER
Free firmware upgrade for EICM and RDM3 manometers
- Adds hysteresis to the live and 10-second average readings
- Free upgrade for manometers
- Installed from an Android phone over Bluetooth with the EIC Firmware Updater app
- Upgrade one manometer, or several at once
What Hysteresis Does
Prevents the manometer readings from jumping around in both the live and average display mode. It uses the past readings to measure a minimum change before updating the screen. We also created a more sophisticated method for zeroing the device to counteract the effects of button presses and hand movement on the sensor.
Without hysteresis: Reading jumps around
With hysteresis: Reading stays steady
Do I need this?
Check your manometer
Turn on your manometer and press the button until you reach the third display. Here you will see the device information including the version. The full hysteresis feature is available in version 0.11 and above. If your manometer is lower than 0.11, follow the instructions below to update the firmware.
How to turn it on
1. Upgrade the firmware
Install the upgrade on your manometer with the EIC Firmware Updater app. See the steps below.
2. Update GammaGuard
Make sure GammaGuard is up to date.
3. Set the hysteresis
In GammaGuard while connected to a manometer, open the device settings and set Live Hysteresis and/or Avg Hysteresis. Enter 0 to turn it off, or a value from 0.1 to 10 Pa (0.0001 to 0.1 inH2O). The default values are 0.1 Pa and 0.0005 inH2O.
Upgrading Your Manometer's Firmware
The EIC Firmware Updater app installs the upgrade over Bluetooth. You’ll need an Android phone running Android 6.0 or later. Each manometer takes a few minutes.
Before you start
- Turn on Bluetooth on your phone.
- Turn the manometer on and keep it close to your phone.
- Disconnect the manometer from GammaGuard or any other app first.
- Keep the manometer powered on until the upgrade finishes.
- Saved settings changed from GammaGuard will not be affected.
Upgrading one manometer
Upgrading several manometers at once
Select several manometers and the app upgrades them one after another. They must all be the same type: all EICM or all RDM3.
- Manometers in a queue restart on their own, so there’s no Confirm and Reboot step.
- Tapping Cancel stops the whole queue. Manometers that already finished keep their new firmware.
Troubleshooting

- Make sure the manometer is turned on and close to your phone.
- Disconnect it from GammaGuard or any other app. The manometer won’t show up while another app is connected to it.
- Scanning stops after 30 seconds. Tap Scan for devices to search again.
- If an update failed, your manometer now shows as “CT008-” followed by the last 4 characters of the Mac.

The manometer didn’t identify itself, which usually means it has no firmware installed yet. Choose the type that matches your unit: EICM for units sold in Canada, RDM3 for units sold in the US.
Warning: choosing the wrong type could damage the hardware. If you’re not sure which one you have, contact us before continuing.

The Bluetooth connection dropped. The app reconnects by itself, up to 3 times, and carries on with the upgrade.
- Move your phone closer to the manometer.
- Keep the manometer turned on, and don’t close the app.

The app couldn’t reconnect to the manometer. Tap OK, then:
- Restart the manometer.
- Move your phone closer to it.
- Tap Scan for devices and run the upgrade again.
- You may be asked to verify the device type.
If Current firmware already shows the latest version, your manometer already has the upgrade. Tap Cancel.
An upgrade that has already started keeps running in the background, and a notification shows its progress. Tap the notification to go back to the app. It’s still best to keep the app open until the upgrade finishes.
The app needs Bluetooth permission to find and connect to your manometer. Depending on your Android version it also needs location permission, and it needs notification permission to show upgrade progress. If you denied a permission, open your phone’s Settings → Apps → EIC Firmware Updater → Permissions and turn it on.
Still stuck? Contact us at [email protected] or (306) 974-6055.